Water pump cycles on and off every few seconds with all taps closed Water & Plumbing
12V diaphragm pump with a 60 litre tank. With everything closed the pump kicks on for about half a second every eight to ten seconds, all night, which is both annoying and clearly not free electrically. No visible drips anywhere under the sink and the floor is dry. Plumbing is push-fit throughout with a filter before the pump. Where's the leak I can't find?
@drainfield_dave · 2mo ago · 3 replies
Short cycling with no visible water almost always means a tiny air or water leak on the pressure side, and the two places it hides are the pump head itself and the joints you can't see.
Diagnostic that takes five minutes: turn the pump on, let it pressurise, then turn the pump off at the switch and open nothing. Come back in ten minutes and turn a tap. If water comes out under pressure, the system held and the problem is likely the pump's internal check valve. If nothing comes out, pressure bled off somewhere and you have a real leak.
Also: fit an accumulator tank. About 30-40 for a small one, plumbed on the pressure side, and it stores enough water under pressure that the pump stops chattering on and off. It smooths the flow at the tap too. On most van builds it's the difference between a pump that's a background annoyance and one you don't think about.
Reply
Report
@two_stroke_tess · 2mo ago
Held pressure fine overnight with the pump off, so it's the check valve. Ordering a rebuild kit rather than a new pump.
Reply
Report
@parquet_pile · 2mo ago
The accumulator is worth fitting regardless. Mine cut pump run time noticeably and the tap stopped pulsing.
Reply
Report