Pump cycles on and off every twenty seconds while the shower is running Pump & Pressure

Submersible pump, 20 gallon bladder tank, 30/50 switch. Since about a week ago the pump kicks on and off roughly every 20 seconds during a shower and the pressure noticeably surges. Tapping the tank sounds solid most of the way up rather than hollow at the top. Nothing else has changed and the water is clear. Is this the tank or the switch, and is running it like this doing damage?

7 answers Share
Report

Answering anonymously — a moderator will review it first.

  • @uptime_hoarder · 3mo ago · 2 replies

    Short cycling is the single most common way people kill a well pump, because it's the startup current that wears the motor, not the running. A pump that starts three times a minute in the shower is doing many times the wear of one that runs continuously for two minutes. Fix it soon rather than at your convenience.

    118
    Share
    Reply

    Answering anonymously — a moderator will review it first.

    Report
    • @skillet_sig · 3mo ago

      Can confirm the expensive way. Ignored a waterlogged tank for two months and replaced a pump instead of a tank.

      52
      Share
      Reply

      Answering anonymously — a moderator will review it first.

      Report
  • @coopvent_cal · 3mo ago · 3 replies

    That's a waterlogged tank, and yes, it's hard on the pump, so I wouldn't leave it for weeks. The bladder has either failed or the air charge has leaked out, and a tank that sounds solid most of the way up is the classic sign. Test it properly: turn off the pump breaker, open a tap to drain the pressure to zero, then check the air valve on top of the tank with a tyre gauge. It should read 2 psi below your cut-in, so 28 for a 30/50. If air comes out fine but reads low, recharge it and see if it holds. If water squirts out of that valve, the bladder is torn and the tank needs replacing.

    152
    Share
    Reply

    Answering anonymously — a moderator will review it first.

    Report
    • @coopvent_cal · 3mo ago

      Bigger is generally better, longer run times and fewer starts. The only limits are space and the fittings. Going to a 40 or 44 gallon is a common upgrade and your pump will thank you.

      68
      Share
      Reply

      Answering anonymously — a moderator will review it first.

      Report
    • @lath_and_lime · 3mo ago

      Water out of the valve. So that's that. Any reason not to go bigger than 20 gallons on the replacement?

      41
      Share
      Reply

      Answering anonymously — a moderator will review it first.

      Report
  • @propolis_pia · 3mo ago

    When you do replace it, set the air charge with the tank empty and the pump off, and check it again once a year. It's a two minute job with a bike pump and a tyre gauge, and it more or less doubles the life of the tank.

    61
    Share
    Reply

    Answering anonymously — a moderator will review it first.

    Report
  • @flux_and_solder · 3mo ago

    Before you buy a tank, also make sure the small tube to the pressure switch isn't clogged with iron or sediment, which produces very similar surging. It's a five minute check and I've seen it be the whole problem twice.

    84
    Share
    Reply

    Answering anonymously — a moderator will review it first.

    Report