How often does a 1000 gallon septic tank actually need pumping for two people

You don't have to guess, you can measure. Have it pumped once now to get a known starting point, then check the sludge depth yourself annually with a stick and a rag, or with a cheap sludge judge tool: you're looking at the depth of solids at the bottom and scum at the top, and the rule of thumb is pump when solids reach about a third of the tank depth or when the scum layer is within a few inches of the outlet baffle. For two adults on 1000 gallons with no disposal, four to five years is a very common real answer, but measuring costs you an hour a year and takes the argument away entirely.

601 · in/well-water ·

Rotten egg smell only from the hot taps and the cold water is completely fine

Hot only means the water heater, essentially always. What's happening is sulphate reducing bacteria living in the tank reacting with the magnesium anode rod and producing hydrogen sulphide, which is your rotten egg smell. Two-part fix that has worked on three houses for me: drain and flush the tank, then swap the magnesium anode rod for an aluminium-zinc one. Some people go to a powered anode instead, which costs more and lasts far longer. Do not just remove the anode and leave it out, the tank will rust through in a couple of years.

341 · in/well-water ·

Pump cycles on and off every twenty seconds while the shower is running

That's a waterlogged tank, and yes, it's hard on the pump, so I wouldn't leave it for weeks. The bladder has either failed or the air charge has leaked out, and a tank that sounds solid most of the way up is the classic sign. Test it properly: turn off the pump breaker, open a tap to drain the pressure to zero, then check the air valve on top of the tank with a tyre gauge. It should read 2 psi below your cut-in, so 28 for a 30/50. If air comes out fine but reads low, recharge it and see if it holds. If water squirts out of that valve, the bladder is torn and the tank needs replacing.

152 · in/well-water ·

Coast number assumed seven percent real and three years in I have got two

7% real is an optimistic input to build a life plan on. I ran mine at 4.5% real and treated anything above that as a bonus, which meant I coasted about two years later than I could have but I've never had this particular conversation with myself. If you rerun your model at 4.5 and the answer is still 'mostly fine, retire at 62 instead of 60', that's probably your real answer.

54 · in/early-retirement ·

Orange staining came back three weeks after shocking the well

Shocking treats bacteria, not iron, so at 1.8 ppm dissolved iron you're going to get that staining back every time regardless of how well you chlorinate. What shocking does help with is iron bacteria, which is a different thing that looks like orange slime rather than staining, and if you had both then the slime went and the iron stayed. You need removal, not disinfection: at that level and that pH, an air injection iron filter or a manganese greensand system is the usual answer, and a softener alone will clog eventually.

89 · in/well-water ·

Clear a 3.9 percent mortgage or keep building the taxable bridge before 55

I'd keep the 3.9% and invest, but with one condition: you have to actually invest it, every month, without touching it. Most people who make the mathematical argument end up with a mortgage and a slightly bigger car. If you know you'll keep the discipline for two years, the numbers are on your side. If you don't, the mortgage is a forced savings plan with a decent return.

108 · in/early-retirement ·

Softener plus iron filter or one cartridge system for two ppm iron on a budget

The honest difference is service intervals and how much iron gets through. A cartridge system at 2.1 ppm and 150 gallons a day will need new cartridges every three to six weeks, which is both a real cost and a chore you will resent by August. The two-stage system handles the iron in a backwashing filter so the softener only has to deal with hardness, which is what softeners are actually good at. If 3,400 is out of reach, the middle path I'd take at 1,500 is a single air injection iron filter now and live with 14 grains of hardness until you can add a softener, rather than trying to make one softener do both jobs.

101 · in/well-water ·