Generator surges up and down under no load after sitting all winter

Almost always, and specifically the idle circuit rather than the main jet. Under load the engine draws through the main jet and everything is fine, which is exactly what you are seeing. At no load it is running on the pilot circuit, and that passage is far smaller and blocks far more easily.

Pull the bowl, remove the pilot jet if yours is removable, and clean it and the small passages around the throttle plate. On many of these the pilot is pressed in and you clean it in place with cleaner and air.

The other candidate is the governor. If cleaning does not settle it, check the linkage for slop and the spring for being stretched or hooked in the wrong hole - a worn linkage hunts because the governor overshoots both ways. But do the carburettor first, given the winter sit.